Modbus RTU Master to KNX TP Gateway - 100 points
  • Intinknxmbm1000100
  • Intinknxmbm1000100
  • Intinknxmbm1000100
INTESIS INKNXMBM1000100

Modbus RTU Master to KNX TP Gateway - 100 points

Product code: INKNXMBM1000100
Integrate any Modbus RTU slave device with any KNX device or system using ETS. The aim of this integration is to make accessible any Modbus registers data and resources from a KNX system, as if it was part of the own KNX system and vice-versa.
Price (Excluding GST)
$P.O.A

Description

FEATURES

  • KNX Certified.
  • Support for Modbus RTU only (RS485).
  • Support for KNX TP.
  • Supports KNX standard datapoints (DPTs) that guarantees a seamless integration with any KNX device or system.
  • Operations for each signal to adapt Modbus register to demanding KNX installations: E.g. multiplication, division and equal to.
  • Reduced dimensions, compact housing.
  • Up to 100 Communication Objects.
  • Up to 255 Modbus Devices.
  • Easy integration & configuration with standard ETS database.

This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features.

Thanks to its support for the KNX standard datapoint types (DPTs) and its flexible Modbus register map, it guarantees a seamless integration with any KNX device or system.

Configured by ETS software. The officially certified ETS database, provides all the necessary parameters to configure both sides of the integration, with up to 100 Modbus registers to integrate into KNX.

Technical Details

Specification

Enclosure

  • Plastic, type ABS (UL 94 V-0)
  • Net dimensions (dxwxh): 71x71x27 mm
  • Colour: White. RAL 9010

Mounting

  • Wall.
  • Power
    • Supplied through KNX bus. See on KNX Port.

    KNX Port

    • 1 x KNX TP-1 Plug-in screw terminal block (2 poles) 2500VDC isolation from other ports. KNX power consumption: 20mA. Voltage rating: 29VDC

    Port A

    • 1 xSerial EIA485 (Plug-in screw terminal block 3 poles) A, B, SGND (Reference ground or shield)
    • 1500VDC isolation from other ports

    Push Button

    • Sets device in programing mode in KNX network

    Operation Temperature

    • 0¡C to +60¡C

    Operational Humidity

    • 5 to 95%, no condensation

    Configuration Jumpers

    • 3 x Jumpers for serial EIA485 configuration:
    • Jumper 1: Connected: 120 ½ termination active. Disconnected: 120 ½ termination inactive.
    • Jumper 2 & 3: Connected: Polarisation active. Disconnected: Polarisation inactive.

    LED Indicators

    • 3 x Onboard LED indicators
    • 2 x Port A TX/RX
    • 1 x KNX Prog Mode.

Properties

Properties

Technology KNX
Brand INTESIS
Mounting Surface
IP rating IP20