Daikin VRV and Sky systems to BACnet MSTP Interface
  • Intinbacdai001r100
  • Intinbacdai001r100
  • Intinbacdai001r100
INTESIS IN485DAI001R000

Daikin VRV and Sky systems to BACnet MSTP Interface

Product code: IN485DAI001R000
The Daikin-BACnet gateway allows fully bi-directional communication between Daikin VRV and Sky Air Conditioner units and BACnet MSTP networks.
Price (Excluding GST)
$P.O.A

Description

FEATURES

  • BTL mark ensures full interoperability with BACnet devices.
  • Support BACnet IP and BACnet MS/TP.
  • Configuration from onboard DIP-switches.
  • Quick and easy installation (plug and set the DP-SW).
  • External power not required.
  • Simultaneous control of the AC unit by the IR remote controller and by BACnet IP or MS/TP.
  • Reduced dimensions 93 x 53 x 58 mm.
  • Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC.
  • Abstraction of Air Conditioning unit properties and functionalities as fixed BACnet Objects.
  • Occupancy function allows energy savings. Costs related to HVAC systems in a building are one of the highest and this type of functions allow to reduce them.
  • Total control and monitoring of the AC unit from BACnet, including AC unitÕs internal variables, running hours counter (for filter maintenance control) and error indication.

DIRECT CONNECTION TO INDOOR UNITS

The gateway is wired directly to a Mitsubishi Electric indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpointÉbut the monitoring of errors, alarms and some internal variables.

FAST AND EASY TO SET UP BY DIP-SW

The product can be installed and set up in a really short time. ItÕs only a matter of wiring the gateway to the AC unit and configure the DIP-SW accordingly. No configuration software and no power supply are required.

Technical Details

Specification

Enclosure: Plastic, type PC (UL 94 V-0). Dimensions: 93mm x 53mm x 58mm. Light Grey. RAL 7035

Weight: 85g.

Mounting: Wall. DIN rail EN60715 TH35.

Terminal wiring (for low-voltage signals):

  • Per terminal: solid wires or stranded wires (twisted or with ferrule)
  • 1 core: 0.5...2.5mm2
  • 2 cores: 0.5...1.5mm2
  • 3 cores: not permitted

BACnet MS/TP port:

  • 1 x Serial EIA485 Plug-in screw terminal block (3 poles + GND):
  • A, B, SG
  • SELV

AC unit port:

  • 1 x RC bus Plug-in screw terminal block (2 poles):
  • P1P2

Switch 1 (SW1): 1 x DIP-Switch for AC features and bus baud rate

Switch 2 (SW2): 1 x DIP-Switch for bus MAC address + temperature magnitude (oC/oF).

Switch 3 (SW3): 1 x DIP-Switch for EIA bus configuration

LED indicators: 2 x Gateway/Communication status

Operational temperature: 0¡C to +70¡C

Stock Temperature: -20oC to +85oC

Operational humidity: 5% to 95%, with no condensation

Stock Humidity: <95% RH, with no condensation

Isolation Voltage: 1500 VDC

Isolation resistance: 1000 M½

Protection: IP20 (IEC60529)

Bus Power Supply: 15VDC, 0.1A PSU shall provide ES1 / PS2 energy source to equipment

External power supply (optional): 12VDC 0,1A NEC Class 2 or Limited Power Source (LPS) and SELV rated Power supply