BACnet IP & MS/TP Client to Modbus TCP & RTU Server Gateway - 250 points
The previous part number for this item was IBOX-MBS-BAC, IBMBSBAC2500000
Description
FEATURES
- UL Certified
- BTL Certified
- Support for up to 5 simultaneous Modbus TCP Clients
- Both Modbus RTU & Modbus TCP
- Both BACnet IP and MS/TP supported
- Possibility to scan for BACnet devices with BACnet Explorer
- Easy integration & updates with Intesis MAPS
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features.
Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed.
The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.
Technical Details
Specification
Enclosure
- Plastic, type PC (UL 94 V-0)
- Net dimensions (dxwxh): 90x88x56 mm
- Recommended space for installation (dxwxh): 130x100x100mm
- Colour: Light Grey. RAL 7035
Mounting
- Wall.
- DIN rail EN60715 TH35.
Terminal Wiring (for power supply and low-voltage signals)
- Per terminal: solid wires or stranded wires (twisted or with ferrule)
- 1 core: 0.5mm2... 2.5mm2
- 2 cores: 0.5mm2... 1.5mm2
- 3 cores: not permitted
Power
- 1 x Plug-in screw terminal block (3 poles)
- 9 to 36VDC +/-10%, Max.: 140mA.
- 24VAC +/-10% 50-60Hz, Max.: 127mA
- Recommended: 24VDC
Ethernet
- 1 x Ethernet 10/100 Mbps RJ45
- 2 x Ethernet LED: port link and activity
Port A
- 1 x Serial EIA485 Plug-in screw terminal block (2 poles) A, B
- 1 x Plug-in screw terminal block green (2 poles). SGND (Reference ground or shield)
- 1500VDC isolation from other ports
Switch A (SWA)
- 1 x DIP-Switch for serial EIA485 configuration:
- Position 1: ON: 120 ½ termination active. Off: 120 ½ termination inactive (default)
- Position 2-3: ON: Polarisation active (default) Off: Polarisation inactive
PORT B
- 1 x Serial EIA232 (SUB-D9 male connector). Pinout from a DTE device. 1500VDC isolation from other ports (except PORT B: EIA485)
- 1 x Serial EIA485 Plug-in screw terminal block (3 poles) A, B, SGND (Reference ground or shield) 1500VDC isolation from other ports. (except PORT B: EIA232)
Switch B (SWB)
- 1 x DIP-Switch for serial EIA485 configuration:
- Position 1: ON: 120 ½ termination active. Off: 120 ½ termination inactive (default)
- Position 2-3: ON: Polarisation active (default) Off: Polarisation inactive
Battery
- Size: Coin 20mm x 3.2mm
- Capacity: 3V / 225mAh
- Type: Manganese Dioxide Lithium
Console Port
- Mini Type-B USB 2.0 compliant
- 1500VDC isolation
USB port
- Type-A USB 2.0 compliant
- Only for USB flash storage device (USB pen drive)
- Power consumption limited to 150mA (HDD connection not allowed)
Push Button
- Button A: Will broadcast I-Am message in the BACnet network.
- Button B: Reserved for future use
Operation Temperature
- 0¡C to +60¡C
Operational Humidity
- 5 to 95%, no condensation
Protection
- IP20 (IEC60529)
LED Indicators
- 10 x Onboard LED indicators:
- 1 x Error LED
- 1 x Power LED
- 2 x Ethernet Link/Speed
- 2 x Port A TX/RX
- 2 x Port B TX/RX
- 1 x Button A indicator
- 1 x Button B indicator
Properties
Properties
| Technology | KNX |
| Brand | INTESIS |
| Mounting | DIN Rail |
| IP rating | IP20 |
| Mounting Width | 6MW |